01. DADOS GERAIS
Produto: | TOTVS Logística TMS
|
---|---|
Linha de Produto: | Linha Protheus |
Segmento: | Logistica |
Módulo: | GESTÃO DE TRANSPORTES (SIGATMS) |
Função: | DOCTO CLIENTE PARA TRANSPORTE (TMSA050) |
Ticket: | 19497136 |
Requisito/Story/Issue (informe o requisito relacionado) : | DLOGTMS02-25527 |
02. SITUAÇÃO/REQUISITO
Ao executar o EDI Automático por Schedule a rotina exibe um error log abaixo:
THREAD ERROR ([3108], 946YAN_DES_TI_ROBERTO_AGENT20, THIS) 03/03/2024 21:54:54
JOB threads doesn't support remote/visual components. in file E:\build-dir\TP11-OF20310-TECXWIN64\interface\srvobject.cpp at line 30
on FWDIALOGMODAL:CREATEDIALOG(FWDIALOGMODAL.PRW) 23/05/2023 15:13:30 line : 223
[build: 7.00.210324P-20230531]
SVN Revision: 38987
[platform: x64]
[appversion: 20.3.1.9]
[environment: 946YAN_DES_TI_ROBERTO]
[thread: 3108]
[dbthread: 11924]
[dbversion: 22.1.1.4]
[dbapibuild: 20220303-20230427]
[dbapiversion: 22.1.1.4]
[dbarch: 64]
[dbso: WINDOWS]
[rpodb: Top]
[localfiles: CTREE]
[remark: Emp :01/0380008 Logged :totvs_scheduler SIGATMS Obj :TMSAE75S - ]
[stack: 146384 bytes]
[memory: 156756096 bytes]
[peak memory: 156756312 bytes]
[threadtype: IPCJobThread]
Called from FWALERT:ACTIVATE(FWALERT.PRW) 23/05/2023 15:13:30 line : 214
Called from __ALERT(FWALERT.PRW) 23/05/2023 15:13:30 line : 525
Called from FWALERTYESNO(FWALERT.PRW) 23/05/2023 15:13:30 line : 369
Called from APMSGYESNO(MSLIB.PRW) 23/05/2023 15:13:33 line : 7336
Called from TMSA050TUDOK(TMSA050.PRW) 02/10/2023 17:55:35 line : 3348
Called from {|| TMSA050TUDOK(NOPCX)}(TMSA050.PRW) 02/10/2023 17:55:35 line : 1112
Called from MSGETDAUTO(MSAUTOPR.PRW) 23/05/2023 15:13:31 line : 787
Called from TMSA050MNT(TMSA050.PRW) 02/10/2023 17:55:35 line : 1112
Called from MBROWSEAUTO(MSAUTOPR.PRW) 23/05/2023 15:13:31 line : 86
Called from TMSA050(TMSA050.PRW) 02/10/2023 17:55:35 line : 251
Called from {|U,V,X,Y,Z| TMSA050(U,V,X,Y,Z)}(TMSAE75.PRW) 01/06/2023 17:20:34 line : 1574
Called from MSEXECAUTO(MATXFUNB.PRX) 29/09/2023 15:18:04 line : 3136
Called from TMSAE75PRE(TMSAE75.PRW) 01/06/2023 17:20:34 line : 1574
Called from TMSAE75PRC(TMSAE75.PRW) 01/06/2023 17:20:34 line : 317
Called from TMSAE75S(TMSAE75S.PRW) 05/09/2022 10:17:19 line : 40
Called from __EXECUTE(APLIB090.PRW) 23/05/2023 15:13:31 line : 721
Called from FWBOSCHDEXECUTE(FWBOSCHDEXECUTE.PRW) 23/05/2023 15:13:33 line : 289
Quando executamos via Menu a mensagem é apresentada e ao confirmar a opção “Sim”, o processo continua e grava a tabela referente o tipo de veículo corretamente
03. SOLUÇÃO
Ajustado o programa para quando executado por Schedule não exibir mensagens de usuário que ocasionam erros na execução do processo.
04. DEMAIS INFORMAÇÕES
Não se aplica
05. ASSUNTOS RELACIONADOS
Não se aplica